2023-2026
900 kg Operating weight
Fuji Galaxy 4-cylinder diesel Engine model
110 kw Gross power
400 V Operating voltage
Diesel Fuel type
260 liter Fuel cap

A 900 kg stationary diesel generator designed for construction sites, commercial facilities, and backup power applications, the Fuji Galaxy FD combines a 110 kilowatt gross engine power rating with 400 V operating voltage and a 260-liter fuel tank. Powered by a Fuji Galaxy 4-cylinder diesel engine, it is intended for supplying electricity to compatible equipment, temporary installations, and facilities requiring standby power. Its stationary configuration and substantial fuel capacity make it practical for site offices, workshops, commercial buildings, and other locations requiring a dedicated generator.

Operating weight 900 kg

Gross engine power 110 kilowatt

Operating voltage 400 V

Engine model Fuji Galaxy 4-cylinder diesel

Engine configuration 4 cylinders

Fuel type Diesel

Fuel tank capacity 260 liters

Makana rating

Owner rating

| 3

Market average

AED 45,000

Starting from

AED 25,000

FUJI FD Technical specifications

General

Operating weight

900 kg

Engine model

Fuji Galaxy 4-cylinder diesel

Operating voltage

400 V

Fuel type

Diesel

Engine

Gross power

110 kw

Service refill capacities

Fuel cap

260 liter

Download datasheets

FUJI FD expert review

Reviewer--cover Reviewed by Marcis V. on October 19, 2026

Overview

The Fuji Galaxy FD (2023–2026) is a stationary diesel generator designed for construction sites, commercial facilities, workshops, and backup power applications. With a 900 kg operating weight, 110 kilowatt gross engine power, and 400 V operating voltage, it provides a practical engine-driven power generation platform. Its Fuji Galaxy 4-cylinder diesel engine and 260-liter fuel tank make it suitable for stationary installations where the generator's rated electrical output meets the connected load requirements.

Expert rating: 5 stars

Pros Substantial 260-liter fuel capacity, 400 V operating voltage, and four-cylinder diesel engine configuration for stationary power applications.
Cons The 900 kg weight limits portability, while electrical output, fuel consumption, and alternator specifications need verification for accurate load planning.

Performance & Efficiency

The Fuji Galaxy 4-cylinder diesel engine produces a listed 110 kilowatt gross mechanical power, supplying the power needed to drive the alternator. The 400 V operating voltage is suitable for compatible commercial and industrial electrical systems.

The engine's gross power must not be confused with the generator's usable electrical output. Actual output depends on the alternator's rated kVA and kW, power factor, efficiency, and standby or continuous-duty configuration. These specifications should be checked before determining the loads the generator can support.

The 260-liter fuel tank provides substantial onboard fuel storage, although operating duration depends on electrical load and engine fuel consumption. Proper load distribution, starting-current management, voltage regulation, and electrical protection are important for consistent operation.

Maintenance & Ownership

The Fuji Galaxy FD uses a four-cylinder diesel engine requiring regular oil changes, filter replacement, cooling-system checks, and fuel-system maintenance. Its 260-liter fuel tank should be checked for contamination and fuel deterioration, particularly when the generator is installed for standby operation.

The alternator, control panel, electrical connections, and protective devices require periodic inspection. Operators should monitor vibration, engine temperature, voltage stability, and fluid leaks. Starting batteries, automatic transfer switches, and emergency shutdown functions should also be tested where fitted.

Buyers should review operating hours, servicing records, load-test results, and alternator condition before purchasing a used unit.

Operator Controls & Installation

The Fuji Galaxy FD has a 900 kg operating weight and is designed for stationary installation. A suitable foundation, lifting arrangements, and adequate service clearances are necessary for safe positioning. Its 400 V electrical system requires professional installation with appropriate earthing, circuit protection, and load distribution.

Control panel features vary by configuration. Buyers should check voltage and frequency monitoring, current readings, operating-hour indicators, engine protection, and any automatic starting or transfer switching equipment installed on the unit.

Proper ventilation, exhaust discharge, and fire precautions are essential for diesel generator operation, particularly near buildings and occupied areas.

In Comparison

John Deere 80 kVA: A generator option with a specified 80 kVA electrical rating, allowing buyers to assess compatibility with their calculated electrical loads.
Kubota 15 kVA: A smaller generator option with a 15 kVA electrical rating, suitable for lighter power requirements and selected backup applications.
Fuji Galaxy FD: Combines a 110 kilowatt gross engine power rating, 400 V operating voltage, and 260-liter fuel tank. Its rated electrical output should be confirmed before comparing available generating capacity.

Final Verdict

Rated 5 stars, the Fuji Galaxy FD offers a four-cylinder diesel engine, substantial fuel storage, and a 400 V electrical system within the AED 25,000–45,000 range. It is a practical candidate for construction site power and commercial backup installations, provided its electrical output meets the required load and the engine, alternator, fuel system, and electrical protection equipment are in good condition.

Show less

FUJI FD owner rating

Fuji galaxy FD Stationary generators [2023-2026]

2023-2026

Overall rating

Based on 3 ratings

4.3
performance

4.3

comfort

4.3

fuel efficiency

4.3

safety

4.3

features

4.3

5 stars

33 %

4 stars

67 %

3 stars

0 %

2 stars

0 %

1 stars

0 %

Pros
The 260-liter fuel tank provides substantial fuel storage for construction site and backup power applications.
Cons
Actual runtime cannot be determined without the engine's fuel consumption figures at different electrical loads.
performance

4.0

comfort

5.0

fuel efficiency

4.0

safety

5.0

features

4.0

FUJI FD similar models

Highlight differences
FUJI FD-110
FUJI FD-110
John deere 80 kVA
John deere 80 kVA
Kubota 15 kVA
Kubota 15 kVA
General
Operating weight 900 kg
Operating weight 800 kg
Operating weight 450 kg
Engine model Fuji Galaxy 4-cylinder diesel
Engine model John Deere 4045
Engine model Kubota D1703-BG-EU1
Operating voltage 400 V
Operating voltage 80 kVA
Operating voltage 15 kVA
Fuel type Diesel
Fuel type Diesel
Fuel type Diesel
Years 2023-2026
Years 2020-2026
Years 2013-2018
Market Average AED 45,000
Market Average AED 40,000
Market Average AED 50,000
Price AED 25,000
Price AED 20,000
Price AED 10,000
Engine
Gross power 110 kw
Gross power 98 kw
Gross power 12.7 kw
Service refill capacities
Fuel cap 260 liter
Fuel cap 180 liter
Fuel cap 62 liter

Stationary generators. For sale.

Get the latest from Makana

Subscribe to receive auction dates, exclusive deals, and news in your inbox.

We care about the protection of your data. Read ourPrivacy Policy
Makana logo

Makana connects quality machinery with the global market, ensuring safe transactions for buyers and sellers.

© 2026 Makana. All rights reserved.

build datetime: 11/12/2026, 11:41:06 AM